Monday 10 August 2020

19c Grid Upgrade Pre Check log

[grid@racnode01 grid]$ ./runcluvfy.sh stage -pre crsinst -upgrade -rolling -src_crshome /u01/app/18.3.0.0/grid -dest_crshome /u01/app/19.3.0.0/grid -dest_version 19.7.0.0

 

Verifying Physical Memory ...PASSED

Verifying Available Physical Memory ...PASSED

Verifying Swap Size ...PASSED

Verifying Free Space: racnode02:/usr,racnode02:/etc,racnode02:/sbin ...PASSED

Verifying Free Space: racnode02:/var ...PASSED

Verifying Free Space: racnode02:/tmp ...PASSED

Verifying Free Space: racnode01:/usr,racnode01:/etc,racnode01:/sbin ...PASSED

Verifying Free Space: racnode01:/var ...PASSED

Verifying Free Space: racnode01:/tmp ...PASSED

Verifying User Existence: grid ...

  Verifying Users With Same UID: 54322 ...PASSED

Verifying User Existence: grid ...PASSED

Verifying Group Existence: asmdba ...PASSED

Verifying Group Existence: oinstall ...PASSED

Verifying Group Membership: asmdba ...PASSED

Verifying Group Membership: oinstall(Primary) ...PASSED

Verifying Run Level ...PASSED

Verifying Hard Limit: maximum open file descriptors ...PASSED

Verifying Soft Limit: maximum open file descriptors ...PASSED

Verifying Hard Limit: maximum user processes ...PASSED

Verifying Soft Limit: maximum user processes ...PASSED

Verifying Soft Limit: maximum stack size ...PASSED

Verifying Oracle patch:28553832 ...PASSED

Verifying This test checks that the source home "/u01/app/18.3.0.0/grid" is suitable for upgrading to version "19.7.0.0". ...PASSED

Verifying Architecture ...PASSED

Verifying OS Kernel Version ...PASSED

Verifying OS Kernel Parameter: semmsl ...PASSED

Verifying OS Kernel Parameter: semmns ...PASSED

Verifying OS Kernel Parameter: semopm ...PASSED

Verifying OS Kernel Parameter: semmni ...PASSED

Verifying OS Kernel Parameter: shmmax ...PASSED

Verifying OS Kernel Parameter: shmmni ...PASSED

Verifying OS Kernel Parameter: shmall ...PASSED

Verifying OS Kernel Parameter: file-max ...PASSED

Verifying OS Kernel Parameter: ip_local_port_range ...PASSED

Verifying OS Kernel Parameter: rmem_default ...PASSED

Verifying OS Kernel Parameter: rmem_max ...PASSED

Verifying OS Kernel Parameter: wmem_default ...PASSED

Verifying OS Kernel Parameter: wmem_max ...PASSED

Verifying OS Kernel Parameter: aio-max-nr ...PASSED

Verifying OS Kernel Parameter: panic_on_oops ...PASSED

Verifying Package: kmod-20-21 (x86_64) ...PASSED

Verifying Package: kmod-libs-20-21 (x86_64) ...PASSED

Verifying Package: binutils-2.23.52.0.1 ...PASSED

Verifying Package: compat-libcap1-1.10 ...PASSED

Verifying Package: libgcc-4.8.2 (x86_64) ...PASSED

Verifying Package: libstdc++-4.8.2 (x86_64) ...PASSED

Verifying Package: libstdc++-devel-4.8.2 (x86_64) ...PASSED

Verifying Package: sysstat-10.1.5 ...PASSED

Verifying Package: ksh ...PASSED

Verifying Package: make-3.82 ...PASSED

Verifying Package: glibc-2.17 (x86_64) ...PASSED

Verifying Package: glibc-devel-2.17 (x86_64) ...PASSED

Verifying Package: libaio-0.3.109 (x86_64) ...PASSED

Verifying Package: libaio-devel-0.3.109 (x86_64) ...PASSED

Verifying Package: nfs-utils-1.2.3-15 ...PASSED

Verifying Package: smartmontools-6.2-4 ...PASSED

Verifying Package: net-tools-2.0-0.17 ...PASSED

Verifying Users With Same UID: 0 ...PASSED

Verifying Current Group ID ...PASSED

Verifying Root user consistency ...PASSED

Verifying correctness of ASM disk group files ownership ...PASSED

Verifying selectivity of ASM discovery string ...PASSED

Verifying ASM spare parameters ...PASSED

Verifying Disk group ASM compatibility setting ...PASSED

Verifying Package: cvuqdisk-1.0.10-1 ...PASSED

Verifying Host name ...PASSED

Verifying Node Connectivity ...

  Verifying Hosts File ...PASSED

  Verifying Check that maximum (MTU) size packet goes through subnet ...PASSED

  Verifying subnet mask consistency for subnet "XXX.XX.XX.0" ...PASSED

  Verifying subnet mask consistency for subnet "XXX.XX.XX.0" ...PASSED

Verifying Node Connectivity ...PASSED

Verifying Multicast or broadcast check ...PASSED

Verifying ASM Integrity ...PASSED

Verifying ASM filter driver configuration consistency ...PASSED

Verifying ACFS Driver Checks ...PASSED

Verifying OCR Integrity ...PASSED

Verifying Network Time Protocol (NTP) ...

  Verifying '/etc/chrony.conf' ...PASSED

  Verifying Daemon 'chronyd' ...PASSED

  Verifying NTP daemon or service using UDP port 123 ...PASSED

  Verifying chrony daemon is synchronized with at least one external time source ...PASSED

Verifying Network Time Protocol (NTP) ...PASSED

Verifying Same core file name pattern ...PASSED

Verifying User Mask ...PASSED

Verifying User Not In Group "root": grid ...PASSED

Verifying Time zone consistency ...PASSED

Verifying Time offset between nodes ...PASSED

Verifying VIP Subnet configuration check ...PASSED

Verifying Voting Disk ...PASSED

Verifying resolv.conf Integrity ...PASSED

Verifying DNS/NIS name service ...PASSED

Verifying Daemon "avahi-daemon" not configured and running ...PASSED

Verifying Daemon "proxyt" not configured and running ...PASSED

Verifying loopback network interface address ...PASSED

Verifying Privileged group consistency for upgrade ...PASSED

Verifying CRS user Consistency for upgrade ...PASSED

Verifying Clusterware Version Consistency ...

  Verifying cluster upgrade state ...PASSED

Verifying Clusterware Version Consistency ...PASSED

Verifying Check incorrectly sized ASM Disks ...PASSED

Verifying that default ASM disk discovery string is in use ...PASSED

Verifying Network configuration consistency checks ...PASSED

Verifying /boot mount ...PASSED

Verifying OLR Integrity ...PASSED

Verifying Verify that the ASM instance was configured using an existing ASM parameter file. ...PASSED

Verifying User Equivalence ...PASSED

Verifying RPM Package Manager database ...INFORMATION (PRVG-11250)

Verifying Network interface bonding status of private interconnect network interfaces ...PASSED

Verifying /dev/shm mounted as temporary file system ...PASSED

Verifying File system mount options for path /var ...PASSED

Verifying DefaultTasksMax parameter ...PASSED

Verifying zeroconf check ...PASSED

Verifying ASM Filter Driver configuration ...PASSED

Verifying Systemd login manager IPC parameter ...PASSED

 

Pre-check for cluster services setup was successful.

Verifying RPM Package Manager database ...INFORMATION

PRVG-11250 : The check "RPM Package Manager database" was not performed because

it needs 'root' user privileges.

 

 

CVU operation performed:      stage -pre crsinst

Date:                         Aug 10, 2020 12:03:18 AM

CVU home:                     /u01/app/19.3.0.0/grid/

User:                         grid

No comments: